76 American Dryer Corp. 113188-3
B. SYSTEM PARAMETERS (PROGRAM LOCATIONS)
1. Cycle Adjustment Value from 0 to 99, in increments of one (1).
2. Manually Loaded Auto Cycle (COOL DOWN TIME) from 0 to 99 minutes, in 1 minute increments.
3. Audio Alert 0-10.
4. Lint Cleaning Frequency 1 to 10 hours.
C. FIXED PARAMETERS
1. Spin Time (SPIN TIME) is fixed at 2 minutes in forward and 2 minutes in reverse drive.
2. Dwell (Stop) Time (STOP TIME) is fixed at 5-seconds (in the Auto Mode) and
is not adjustable.