b. Drying Temperature Programmable from 160° F to 200° F (71° C to 93° C,), in one-degree increments,
and preset at 160° F (71° C) for axial dryers.
c. Dryness Level Programmable for FINISHING, DRY, AND EXTRA DRY.
d. Cool Down Time  Programmable from 0 to 99 minutes, in 1 minute increments.
e. Cool Down Temperature Programmable from 70° F to 100° F (21° C to 38° C), in one-degree
increments.
f. Cycle Adjustment  Programmable from 0 to 99.
2.
Timed (Manual) Cycle
a. The Phase 7 non-coin microprocessor controller (computer) can be programmed to reverse or not
reverse. This is done in the DRYER SETUP parameter.
b. Drying Time Programmable from 0 to 99 minutes, in 1 minute increments.
c. Drying Temperature Programmable from 100° F to 200° F (38° C to 93° C) in one-degree increments
for a radial dryer, and 100° F to 160° F (38° C to 71° C) in one-degree increments for an axial dryer.
d. Cool Down Time  Programmable from 0 to 99 minutes, in 1 minute increments.
e. Cool Down Temperature Programmable from 70° F to 100° F (21° C to 38° C), in one-degree
increments.
f. The Spin Time can be programmed from 30-seconds to 120-seconds, in 1-second increments.
g. The Dwell (Stop) Time can be programmed from 5-seconds to 10-seconds, in 1-second increments.
h. Steam Injection (Optional) Programmable 0-5 intervals.
ALL six (6) A-F preprogrammed cycles, along with cycles 0-40, have been programmed by the
factory as outlined in Section VII. However, even though cycles A-F are the most common cycles
used, they should be reviewed to ensure they meet the location application or needs. Should changes
become necessary, refer to the Programming Section of this manual.
B. MANUALLY LOADED CYCLES
For occasional or onetime special loads, the operator must enter the specific program features needed. This
cycle is not stored within the Phase 7 non-coin microprocessor controller (computer) and must be entered each
time.
The Manually Loaded Cycle can be set in either the Automatic Drying Mode (Patent No. 4,827,627) or the
Timed (Manual) Drying Mode. These modes are selected by pressing the AUTO or MAN key on the
keyboard (touch pad).